电气导线的敷设应按装修设计规定进行施工,配线时,相线(L)宜用红色,零线(N)宜用蓝色,接地保护线应用黄绿双色线(PE)。http://bbs.0513zs.com/attachments/dvbbs/2006-7/2006732234935792.jpg
http://bbs.0513zs.com/attachments/dvbbs/2006-7/20067322341891279.jpg
当然不一定非要用红色线和蓝色线用做相线(火线)和零线,象下面这张图片里这样,用蓝色线和绿色线做火线和零线也是可以的,只是用红色线和蓝色线更规范而已。
http://bbs.0513zs.com/attachments/dvbbs/2006-7/20067322344725149.jpg
不管用什么颜色的线,有一点必须遵循,即:同一住宅内配线颜色应统一。 <p><strong><font color="#555555"><font size="4"><span>室内布线应该穿管敷设,不应该有电线外露<font face="宋体">(除现浇混凝土楼板顶面可采用护套线外)</font></span></font></font><span lang="EN-US" style="FONT-SIZE: 10.5pt; mso-bidi-font-family: Arial;"><p></p></span></strong></p><img src="attachments/dvbbs/2006-7/20067322571631959.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/> <p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;"><font color="#555555" size="4"><strong>管内导线总截面积不应超过和管内径截面积的<span lang="EN-US">40</span>%。</strong></font></span></p><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;"><span lang="EN-US"><p></p></span></span> </p><img src="attachments/dvbbs/2006-7/20067323114266781.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;">这根<span lang="EN-US">4</span>分线管(内径<chmetcnv wst="on" tcsc="0" numbertype="1" negative="False" hasspace="False" sourcevalue="16" unitname="mm"><span lang="EN-US">16mm</span></chmetcnv>)内居然穿了<span lang="EN-US">6</span>根电线,已经远不止线管截面积的<span lang="EN-US">40</span>%了。最容易出现此问题的地方就是浴霸穿线处。</span><span lang="EN-US" style="mso-bidi-font-size: 10.5pt;"><p></p></span></p> <font size="4"><strong>暗盒与线管必须通过锁母连接</strong></font><img src="attachments/dvbbs/2006-7/20067323441279896.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/2006732346091766.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/> <p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;"><font color="#555555" size="4"><strong>空调电插座、厨房电源插座、卫生间电源插座、其它电源插座及照明电源均应设计单独回路。</strong></font></span></p><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;"></span> </p><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;"><span lang="EN-US"><p></p></span></span> </p><img src="attachments/dvbbs/2006-7/2006740211792512.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/2006740212730616.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;">某业主家应该有<span lang="EN-US">8</span>个回路:<span lang="EN-US">4</span>个空调电源插座<span lang="EN-US">+</span>厨房电源插座<span lang="EN-US">+</span>卫生间电源插座<span lang="EN-US">+</span>其它电源插座<span lang="EN-US">+</span>照明电源。可配电箱内只有<span lang="EN-US">7</span>个回路。经查,原来是主卧和次卧的空调电源共用了一个回路。这属于不规范施工。</span><span lang="EN-US" style="mso-bidi-font-size: 10.5pt;"><p></p></span></p> <p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;"><font color="#555555" size="4"><strong>吊平顶内的电气配管,应采用明管敷设,不得将配管固定在平顶的吊杆或龙骨上。灯头盒、接线盒的设置应便于检修,并加盖板。使用软管接到等位的,其长度不应超过<chmetcnv unitname="m" sourcevalue="1" hasspace="False" negative="False" numbertype="1" tcsc="0" wst="on"></chmetcnv><span lang="EN-US">1m</span><chmetcnv></chmetcnv>。软管两端应用专用接头与接线盒,灯具应连接牢固。各种强、弱电的导线均不得在吊平顶内出现裸露。</strong></font></span></p><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;"></span> </p><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-bidi-font-size: 10.5pt;"></span><span lang="EN-US" style="mso-bidi-font-size: 10.5pt;"><p></p></span></p><p></p> <p></p><p><img src="attachments/dvbbs/2006-7/200674174073510.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/></p><p> </p><p><img src="attachments/dvbbs/2006-7/200674182369910.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>未使用灯头盒</p><p> </p><p><img src="attachments/dvbbs/2006-7/200674185030079.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>吊顶内电线应用线管敷设到位。不应该留下这样的“半拉子”工程。</p><p> </p><img src="attachments/dvbbs/2006-7/200674111538038.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>软管长度超过1米。
[此贴子已经被作者于2006-7-4 1:16:56编辑过] <p><font color="#555555" size="4"><strong>线路施工结束后,所有的线管须做临时固定和保护。</strong></font></p><p> </p><p><img src="attachments/dvbbs/2006-7/2006741175074309.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>地面的线管用铁丝固定。</p><p> </p><img src="attachments/dvbbs/2006-7/2006741181810947.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/2006741185168985.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/> <p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><font color="#555555"><font face="Times New Roman"><strong><font size="4"><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';">电线导管与水管在同一平面间距大于</span><chmetcnv wst="on" tcsc="0" numbertype="1" negative="False" hasspace="False" sourcevalue="100" unitname="mm"><span lang="EN-US">100mm</span></chmetcnv><span lang="EN-US">,</span><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';">,不同平面间距大于</span><chmetcnv wst="on" tcsc="0" numbertype="1" negative="False" hasspace="False" sourcevalue="50" unitname="mm"><span lang="EN-US">50mm</span></chmetcnv><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';">。</span></font></strong></font></font></p><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';"></span> </p><p><img src="attachments/dvbbs/2006-7/200677111314766.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>洗衣机水管与插座线路共用一根墙面开槽!!!为将来留下安全隐患。</p><p> </p><p><img src="attachments/dvbbs/2006-7/200677113727136.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>地面水管与电线导管并排布线!!!</p><p> </p><img src="attachments/dvbbs/2006-7/200677114052287.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>电线管与水管交叉处尽量做到电线管在水管之上。 <p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';"><font color="#555555" size="4"><strong>穿越厅堂、卧室的水管尽量从顶面走。</strong></font></span></p><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';"></span> </p><img src="attachments/dvbbs/2006-7/2006771384474898.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';">这样水管一旦渗漏,一方面可以及时觉察到(不用楼下邻居上门兴师问罪时才知道自家水管在漏水),另一方面维修起来也不用兴师动众去破坏地面装饰材料了(实木地板和地砖)。</span></p>
[此贴子已经被作者于2006-7-7 2:12:40编辑过] <p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';"><font color="#555555" size="4"><strong>电线导管弯管必须采用冷弯,弧度圆滑。不允许用直角弯及三通。</strong></font></span></p><p class="MsoNormal" style="MARGIN: 0cm 0cm 0pt;"><span style="FONT-FAMILY: 宋体; mso-ascii-font-family: 'Times New Roman'; mso-hansi-font-family: 'Times New Roman';"></span> </p><p><img src="attachments/dvbbs/2006-7/2006772145119826.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/2006772151329277.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>这样的弯管电线如何穿的过去?</p><p> </p><p><img src="attachments/dvbbs/2006-7/2006772155149867.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>三通现在倒是很少见了。</p><p> </p><img src="attachments/dvbbs/2006-7/2006772161917142.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>其实工程上的弯管是通过两个45度弯来完成一个90度的弯,这样电线能够很容易的抽拉出来。 <p><font color="#555555" size="4"><strong>强弱线管间距30cm</strong></font></p><p> </p><img src="attachments/dvbbs/2006-7/2006790405240753.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/200679041820692.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/2006790411740721.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /> <p><font color="#555555" size="4"><strong>厨房、卫生间的电线管尽量不要从地面布线。</strong></font></p><p> </p><img src="attachments/dvbbs/2006-7/2006791125275629.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/200679113451359.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>厨房卫生间的电线管尽量从顶面和墙面走线。 <p>电路施工结束后裸露在外打线头卷进线盒,凡带电线头必须用绝缘胶带包裹。</p><p> </p><img src="attachments/dvbbs/2006-7/200671221284522639.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/> <p>好像不是我家的现场</p> <p><font color="#555555" size="4"><strong>电路施工时,线槽开好后,先用水泥砂浆将线盒固定,再穿管放线。</strong></font></p><p> </p><img src="attachments/dvbbs/2006-7/200671223124338262.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/200671223125284213.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /> <div class="msgheader">QUOTE:</div><div class="msgborder"><b>以下是引用<i>摸黑赶路</i>在2006-7-12 23:16:16的发言:</b><br/><p>好像不是我家的现场</p></div><p></p>哈哈,16楼那个是你家的现场,你家的水电工总体来说做的是相当不错的了。 <p><font color="#555555" size="4"><strong>同一回路的线径必须相同。</strong></font></p><p> </p><img src="attachments/dvbbs/2006-7/20067130574598640.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/>火线与零线是4平方的,而接地线确是2.5平方的。 顶个先 <p><font color="#555555" size="4"><strong>电气施工结束后,配电箱内各线路连接到位,走线清晰。</strong></font></p><p> </p><img src="attachments/dvbbs/2006-7/20067140562286798.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/><img src="attachments/dvbbs/2006-7/20067140563474784.jpg" border="0" onclick="zoom(this)" onload="if(this.width>document.body.clientWidth*0.5) {this.resized=true;this.width=document.body.clientWidth*0.5;this.style.cursor='pointer';} else {this.onclick=null}" alt="" /><br/> <p>再顶!</p><p>为了保证正常的照明用电,建议照明回路的控制开关在漏电开关前(如20楼两图所示)</p><p>这样接法的好处是:不会因为其他回路过流跳闸,而漆黑一片!</p> <p>这么好的帖我怎么才看到啊.</p><p>还来得及:) 没错过就好:)</p><p>记在脑子里了!</p> 穿越厅堂卧室的管子从顶面走是从楼顶过线? 又看了一次,的确是好贴。 穿越厅堂,卧室水管从顶面走? 不懂 <p>顶</p><p></p> 哇这么多,今晚回家实践下 呵呵 好贴啊! 好贴!真是及时雨,我马上要用到了。顶! 还是不懂!装修完了我可以改行做电工了! <p>顶顶顶</p><p>下半年就用到</p>